{"product_id":"quartz-flow-cell-32ul","title":"MQ10-F Aluminum-Clad Quartz Flow Cell 32uL 10mm Path for UV-Vis Spectrophotometer","description":"\u003ch4\u003eAluminum-Clad Quartz Flow Cell 32μL | 10mm Path Length | UV-Vis-NIR Full Spectrum | OEM ODM Service\u003c\/h4\u003e\n\u003cp\u003ePrecision-engineered fused quartz flow cell with aluminum protective jacket, 32μL effective volume, 10mm optical path and 200-2500nm full-spectrum transmittance ≥90%. Standard 35×12.5×12.5mm dimensions fit most spectrophotometers and biochemistry analyzers. Custom design, OEM ODM and rapid sample service available. Ideal for UV-Vis spectroscopy, biochemical analysis, environmental monitoring and laboratory research applications.\u003c\/p\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eOur MTQ10-F aluminum-clad quartz flow cell is built with precision optical engineering for continuous spectroscopic analysis across UV-Vis-NIR full spectrum. The fused quartz core delivers ≥90% transmittance from 200nm to 2500nm with no absorption in the UV region, while the external aluminum jacket provides robust impact resistance and thermal stability for frequent handling and long-term instrument integration.\u003c\/p\u003e\n\u003cp\u003eWe are a research-driven technical supplier rather than a traditional manufacturer. We provide full design support, material selection and strict quality inspection. You get consistent precision and stable performance without the extra costs of managing production lines yourself.\u003c\/p\u003e\n\u003ch2\u003eMain Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f5f7fa;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; width: 40%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; width: 60%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eMETICULAB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eMQ10-F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eMaterial\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eHigh-purity fused quartz + aluminum jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eOuter Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e35 × 12.5 × 12.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eOptical Path Length\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eEffective Volume\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e32 μL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eBore Diameter\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e1.5mm\/2mm\/3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eCenter Height (Z-height)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eSpectral Range\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e200-2500 nm (UV-Vis-NIR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eTransmittance\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e≥90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eTolerance (Outer Dim.)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e±0.02mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eTolerance (Path Length)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e±0.01mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhy Choose METICULAB MTQ10-F\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-purity fused quartz glass, no UV absorption from 200nm to 2500nm\u003c\/li\u003e\n\u003cli\u003eAluminum cladding protects against impact, thermal shock and breakage\u003c\/li\u003e\n\u003cli\u003e32μL micro-volume dramatically reduces reagent and sample consumption\u003c\/li\u003e\n\u003cli\u003eInternally polished flow path eliminates liquid residue and carryover\u003c\/li\u003e\n\u003cli\u003eStandard 35×12.5×12.5mm dimensions, direct drop-in replacement for most instruments\u003c\/li\u003e\n\u003cli\u003eFull customization available for volume, path length, bore diameter and outer dimensions\u003c\/li\u003e\n\u003cli\u003eEvery unit inspected for dimensional tolerance, transmittance and seal integrity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplication Scope\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUniversity and institutional research labs for UV-Vis-NIR spectroscopy\u003c\/li\u003e\n\u003cli\u003eWater quality monitoring (COD, ammonia nitrogen, heavy metals)\u003c\/li\u003e\n\u003cli\u003ePharmaceutical raw material purity analysis and formulation QC\u003c\/li\u003e\n\u003cli\u003eFood colorant and additive quality control\u003c\/li\u003e\n\u003cli\u003eChemical reaction monitoring and process control\u003c\/li\u003e\n\u003cli\u003eOEM replacement parts for spectrophotometers and biochemistry analyzers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCooperation Workflow\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eShare your requirements, drawings or instrument specifications\u003c\/li\u003e\n\u003cli\u003eWe provide technical evaluation and formal quotation\u003c\/li\u003e\n\u003cli\u003eSample production for your performance testing\u003c\/li\u003e\n\u003cli\u003eMass production after sample confirmation\u003c\/li\u003e\n\u003cli\u003eLong-term technical support available\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the minimum order quantity?\u003c\/strong\u003e\u003cbr\u003eA: MOQ is 10 pieces. Sample orders are welcome for testing before bulk purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Do you provide OEM ODM service?\u003c\/strong\u003e\u003cbr\u003eA: Yes, full OEM ODM support including custom volume, path length, bore diameter, outer dimensions and private labeling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between MTQ10-F and MTG10-F?\u003c\/strong\u003e\u003cbr\u003eA: MTQ10-F is fused quartz with aluminum jacket for UV-Vis-NIR full spectrum (200-2500nm). MTG10-F is optical glass for visible spectrum only (380-780nm). Choose quartz for UV applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the lead time?\u003c\/strong\u003e\u003cbr\u003eA: Standard items in stock ship within 48 hours. Custom orders take 7-15 working days based on quantity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do you guarantee product quality?\u003c\/strong\u003e\u003cbr\u003eA: Every unit undergoes dimensional tolerance, transmittance and seal integrity testing before shipment. Full inspection report provided with each batch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What instruments are compatible with MTQ10-F?\u003c\/strong\u003e\u003cbr\u003eA: Fits most UV-Vis spectrophotometers, biochemistry analyzers and online monitoring systems with standard 35mm mounting slot. Direct replacement, no modification needed.\u003c\/p\u003e\n\u003ch2\u003eContact METICULAB\u003c\/h2\u003e\n\u003cp\u003eSend your requirements or instrument specifications for fast technical evaluation and custom solutions.\u003c\/p\u003e\n\u003cp\u003e📧 Email: choikyuc@gmail.com  |  info@meticulab.net\u003cbr\u003e📞 WhatsApp \u0026amp; KakaoTalk: +82-10-3988-4813\u003cbr\u003e🌐 Official Website: https:\/\/meticulab.net\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; color: #666; border-top: 1px solid #eee; padding-top: 12px;\"\u003e\u003cem\u003eGlobal Supplier from South Korea. OEM customization and NDA confidential service available.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eThis content is compiled by METICULAB technical team.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eMETICULAB focuses on R\u0026amp;D, sales and after-sales service of precision optical flow cells and laboratory consumables.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eAdvantages: stable precision, short production cycles, complete after-sales support, competitive cost performance.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eInstrument manufacturers, research labs and equipment suppliers welcome to inquire about sample testing and custom solutions.\u003c\/em\u003e\u003c\/p\u003e","brand":"METICULAB","offers":[{"title":"Default Title","offer_id":49218479227132,"sku":null,"price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0791\/7695\/8204\/files\/MT_Quartz_Flow_Cell.png?v=1782110288","url":"https:\/\/meticulab.myshopify.com\/ko\/products\/quartz-flow-cell-32ul","provider":"METICULAB","version":"1.0","type":"link"}