Skip to product information
1 of 1

Meticulab

Meticulab Ultrasonic DNA Shearer 8 – Focused Ultrasonicator for DNA/RNA Fragmentation (OEM/ODM Available)

Meticulab Ultrasonic DNA Shearer 8 – Focused Ultrasonicator for DNA/RNA Fragmentation (OEM/ODM Available)

Quantity

🔧 OEM/ODM Manufacturing – Customizable for Your Brand

We offer comprehensive customization services for nucleic acid fragmentation equipment. Help distributors, NGS kit manufacturers, and equipment brands develop their own fragmentation solutions with custom branding, software, and hardware configurations. Minimum order quantities apply for white-label and custom configurations.

Meticulab Ultrasonic DNA Shearer 8 – Focused Ultrasonicator for DNA/RNA Fragmentation

OEM/ODM Customizable | Private Label Available | White-Label Solutions

✅ Why Partner with Meticulab for OEM/ODM Fragmentation Solutions?

  • Private Label & White-Label: Your logo, colors, and packaging – ready for your brand identity
  • Custom Throughput: Higher sample capacity (e.g., 96-well format) available upon request
  • Software & Hardware Customization: Tailored protocols, user interface, and mechanical modifications
  • Integration Support: API for robotic integration and automated workflow compatibility
  • Full Confidentiality: Your designs and IP are protected; manufacturer details never disclosed

The Meticulab Ultrasonic DNA Shearer 8 is a high-precision focused ultrasonicator designed for DNA and RNA fragmentation in next-generation sequencing (NGS) workflows. Utilizing advanced Adaptive Cylindrical Ultrasonic (ACU) technology, it delivers consistent, reproducible fragment sizes with minimal sample handling.

This system can process 1 to 8 samples simultaneously, making it ideal for low-to-medium throughput laboratories. It accommodates standard 8-tube strips or single tubes, eliminating the need for expensive proprietary consumables. The non-contact processing ensures no cross-contamination and simplifies workflow integration.

✨ Key Features

  • Adaptive Cylindrical Ultrasonic (ACU) Technology: Delivers consistent fragmentation profiles (200-600bp typical for chromatin)
  • Flexible Throughput: Process 1 to 8 samples in a single run
  • Non-Contact Processing: No cross-contamination, no aerosols, no cleanup required
  • Standard Consumables: Use common 8-tube strips or single tubes – no special consumables needed
  • Direct Plate Transfer: Samples can be transferred directly from standard plates without manual intervention
  • Quiet Operation: Low noise and vibration-free
  • Excellent Reproducibility: High consistency across 1-8 samples
  • Fatigue-Resistant: Designed for continuous long-duration operation
  • CB and CE Certified: Compliant with international safety standards

🔬 Applications

  • DNA shearing for NGS library preparation
  • Chromatin shearing for ChIP-seq
  • RNA fragmentation for RNA-seq
  • FFPE sample fragmentation
  • Cell lysis and nucleic acid extraction

🛠 Technical Specifications

Specification Details
Sample Throughput 1–8 samples per run
Fragment Size Range 100 bp – 5 kb (adjustable via parameters)
Sample Volume 30–150 μL (extendable to milliliter scale)
Technology ACU™ (Adaptive Cylindrical Ultrasonic)
Supported Consumables 8-tube strips, single tubes, standard PCR plates (with adapter)
Automation Integration Optional (can be integrated into automated workflows)
User Interface Touch screen
Dimensions (W×D×H) 438 mm × 417 mm × 385 mm
Weight 25 kg
Power Requirements 220V/50Hz or 110V/60Hz
Operating Environment 10°C to 30°C, 20–80% humidity, 80–106 kPa

⚙️ OEM/ODM Customization Options

  • Private Label & Branding: Your logo, colors, and packaging
  • White-Label Solutions: Ready for your brand identity
  • Custom Throughput: Higher sample capacity (e.g., 96-well format) available upon request
  • Software Customization: Tailored protocols and user interface
  • Consumable Adaptation: Optimized for specific tube/plate types
  • Integration Support: API for robotic integration
  • Mechanical Modifications: For specialized applications

📦 Ordering Information

  • Standard Models: Available for immediate delivery
  • OEM/ODM Orders: Minimum quantities vary by customization level
  • Evaluation Units: Available for qualified partners

Contact our OEM/ODM specialists to discuss your fragmentation requirements and receive a customized quotation.

❓ Frequently Asked Questions

Q: What fragment sizes can this system achieve?
A: The system can generate fragments ranging from 100 bp to 5 kb depending on the parameters. Typical chromatin shearing yields 200-600 bp fragments suitable for ChIP-seq.

Q: Can I use my own consumables?
A: Yes! The system is designed to work with standard 8-tube strips and single tubes. No proprietary consumables are required, significantly reducing running costs.

Q: How many samples can I process at once?
A: The standard model processes 1 to 8 samples per run. Higher throughput versions (e.g., 96-well) are available for OEM/ODM customization.

Q: Is this instrument compatible with automated workflows?
A: Yes, the system can be integrated into automated liquid handling workstations. API and integration support are available for OEM partners.

Q: Do you offer private labeling?
A: Absolutely. We provide comprehensive OEM/ODM services including private labeling, white-label solutions, and custom modifications. Contact us with your requirements.

📋 Important Information

  • For research use only. Not for diagnostic or clinical applications.
  • To protect our OEM/ODM partners, manufacturer names and internal model numbers are not disclosed.
  • All products are supplied under the Meticulab quality management system.
  • Product names, logos, and brands mentioned are for identification purposes only and are the property of their respective owners.

📩 Get a Quote

Contact our OEM/ODM specialists to discuss your fragmentation requirements and receive a customized quotation.

📧 Email:info@meticulab.net
📞 Phone / WhatsApp / KakaoTalk: +82-10-3988-4813

View full details