Skip to product information
1 of 5

METICULAB

UV Bandpass & Edge Filters 190nm-450nm for Mercury Line & Excimer Laser Systems

UV Bandpass & Edge Filters 190nm-450nm for Mercury Line & Excimer Laser Systems

Quantity

UV Bandpass & Edge Filters

190nm–450nm · Narrow Bandpass · Long-Pass · Short-Pass

For Mercury i-Line, Excimer Laser & Semiconductor Lithography Systems

190–450nm UV Coverage

Deep UV to near-UV for mercury & excimer applications.

Multiple Filter Types

Narrow bandpass · Long-pass · Short-pass.

Key Wavelengths Available

190nm · 254nm · 308nm · i-line 365nm.

Quartz & Fused Silica Substrates

Excellent UV transmission & thermal stability.

Steep Edge Transition

High out-of-band blocking for clean spectral separation.

Full Customization

Center wavelength · Bandwidth · Size · Substrate.

Product Description

The METICULAB UV Filter series provides precision spectral filtering for i-line steppers, mercury lamp systems, and excimer laser applications. Available in narrow bandpass, long-pass, and short-pass configurations, these filters deliver high transmission with steep edge transitions and excellent out-of-band blocking across the 190nm–450nm range.

Whether you need to extract specific mercury spectral lines, block unwanted wavelengths in lithography systems, or protect optical components in high-power laser environments, METICULAB UV filters provide reliable, high-performance solutions tailored to your system requirements.

Core Feature: "Precise wavelength extraction with superior out-of-band rejection" — critical for photolithography and high-precision spectroscopy.

Available Filter Types

Narrow Bandpass

Mercury i-line & spectral line extraction with high rejection.

Long-Pass

Transmit above cutoff wavelength, block shorter wavelengths.

Short-Pass

Transmit below cutoff wavelength, block longer wavelengths.

Key Wavelengths Available

  • 190nm — High-transmission filter for deep UV applications
  • 254nm — Mercury line filter for sterilization and spectroscopy
  • 308nm — Excimer laser window for XeCl laser systems
  • 365nm (i-line) — Mercury i-line filter for photolithography
  • Custom wavelengths available upon request

Applications

  • Photolithography and microfabrication
  • Defect detection and semiconductor inspection
  • Fluorescence excitation and spectroscopy
  • Excimer laser processing systems
  • Environmental monitoring instruments
  • Research and development laboratories

Specifications

Wavelength Range 190nm – 450nm
Filter Types Narrow Bandpass / Long-Pass / Short-Pass
Substrate Material Fused Silica / Quartz
Coating Technology Ion-Beam Reactive Sputtering
Standard Wavelengths 190nm, 254nm, 308nm, 365nm (i-line)
Out-of-Band Blocking High (OD ≥ 4 typical)
Surface Quality 60/40 or better
MOQ 10 pieces

Customization & Support

At METICULAB, we offer full OEM/ODM customization for UV filters including center wavelength, bandwidth, size, substrate material (Fused Silica, Quartz), and transmission specifications. Our technical team provides design consultation and application support to ensure optimal spectral performance in your system.

Why METICULAB?

  • Precision ion-beam sputtering — sharp edges and high durability
  • R&D-Friendly MOQ — as low as 10 pieces for prototype testing
  • 100% spectral performance verification — every batch tested before shipment
  • Quality issues covered by replacement guarantee
  • Technical support for integration and application optimization
  • Global shipping via DHL, FedEx, UPS

Frequently Asked Questions

Q1: What filter types do you offer?

A: We offer narrow bandpass, long-pass, and short-pass filters covering the 190nm–450nm UV range.

Q2: What wavelengths are available as standard?

A: Standard wavelengths include 190nm, 254nm, 308nm (excimer), and 365nm (i-line). Custom wavelengths are also available.

Q3: Can I customize center wavelength and bandwidth?

A: Yes. We offer full customization for center wavelength and bandwidth based on your optical system design requirements.

Q4: What substrate material do you recommend for UV filters?

A: We recommend Fused Silica or Quartz for excellent UV transmission and thermal stability in high-power applications.

Q5: What is your MOQ?

A: Our standard MOQ is 10 pieces for optical filters. For R&D purposes, we can accommodate smaller quantities upon request.

Q6: How do you ensure product quality?

A: Every batch undergoes independent spectral performance verification before shipment. We also provide a replacement guarantee for any quality issues.

Q7: Are these filters compatible with high-power UV lasers?

A: Yes. Our ion-beam sputtering coating provides excellent durability for high-power UV laser applications, including excimer lasers.

Q8: What is your typical lead time?

A: Standard items are typically shipped within 7-15 working days. Custom orders require 15-25 working days after drawing confirmation.

METICULAB

Precision Lab Solutions

📧 choikyuc@gmail.com / info@meticulab.net
📞 WhatsApp & KakaoTalk: +82-10-3988-4813
🌐 www.meticulab.net

View full details